Insulation Calculator

Target R-value and insulation type in; depth, bags or board feet out.

Your numbers
Your project

Insulation needed

Enter your numbers above.

How much insulation you need

Insulation is rated by R-value, its resistance to heat flow, and R-values of layers simply add. So the calculator subtracts what you already have from your target and divides by the R-value per inch of the product: depth = (target R − existing R) ÷ R per inch.

The per-inch values are typical figures from the U.S. Department of Energy's Energy Saver guidance: about R-3.2 to 3.8 for loose-fill cellulose, R-2.2 to 2.7 for loose-fill fiberglass, R-2.9 to 4.3 for fiberglass batts, about R-3.6 for open-cell and R-6 to 7 for closed-cell spray foam. Your product's label is the final word, since it lists the settled thickness needed for each R-value.

For attics, ENERGY STAR recommends R-49 to R-60 across most of the country and R-30 to R-49 in the warmest zones. The cellulose bag count scales from a manufacturer's published coverage chart (roughly 47 bags of 25 lb per 1,000 sq ft to reach R-38), so treat it as a planning number and confirm with the chart on the bag you buy.

Where these numbers come from

The formulas and default values in this calculator are based on:

  • U.S. Department of Energy, Energy Saver insulation materials guide
  • ENERGY STAR recommended home insulation R-values by climate zone
  • National Fiber cellulose bag coverage chart

These are planning estimates. Check product labels, your local building code, and a licensed contractor before you buy materials or build.

Frequently asked questions

How do I know what R-value my attic has now?

Measure the depth of the existing insulation in a few places and multiply by the per-inch value for its type. Gray or tan fluffy fiber is usually cellulose; pink, yellow or white fiberglass is fiberglass. Old, compressed insulation performs below its original rating.

Can I put new insulation on top of old?

Usually yes, as long as the old insulation is dry and free of mold or pests. Lay new batts without a paper or foil facing when you add them over existing insulation, so you don't trap moisture between layers.

Why does blown insulation need to be deeper than the label R-value suggests?

Loose-fill settles over time. Manufacturers list both an installed and a settled thickness; blow in to the installed thickness so the attic still reaches your target R-value after it settles.